How to fix the thermostat on Dingxin water heater
This part illustrates how to replace the thermostat of a vertical wall mounting machine.
1. Loosen the screw of the maintenance cover at the bottom of the machine and remove the maintenance cover.
2. Pull out the thermostat probe tube in the blind pipe of the heating tube.
3. Put the machine upside down, remove the control knob connected to the thermostat,peel off the sticker, and loosen the fixing screws between the thermostat and the control panel cover to separate apart.
4. Use needle-nose pliers to pull out the terminals connecting the two terminal blocks of the thermostat inside the control panel, and remove the thermostat from the internal space of the end cover.
5. Replace with a new thermostat, connect to the two terminal blocks of the thermostat, and tighten the fixing screws between the thermostat and the control panel cover, and recover sticker marking on the top. Furthermore,the temperature control knob should be fixed on the thermostat rod again.
6. Reinsert the temperature probe of the thermostat into the blind pipe of the heating pipe, and plug the blind pipe with a rubber seal to prevent the relative movement of the probe.
7. Install the maintenance cover, tighten the screws, and the installation is complete
For more details on maintenance skill,you can check video uploaded on youtube:
https://youtu.be/VY83ooyCsYY
How to fix the thermal cut on Dingxin water heater
This part illustrates how to replace the temperature thermal cut of a vertical wall mounting machine.
1. Loosen the screws of the maintenance cover at the bottom of the machine and remove the maintenance cover.
2. Unscrew the fixing screw between the temperature thermal cut and the heating element flange, and pull the temperature thermal cut probe tube out of the heating tube blind pipe.
3. Use needle-nose pliers to disconnect the four terminal blocks connecting the thermal cut.
4. Replace with a new temperature thermal cut, extend its temperature probe into the blind pipe of the heating pipe, and block the blind pipe with a rubber plug to prevent the relative movement of the probe pipe. Tighten the fixing screws of the thermal cut to fixing seat of tank flange,
5. Install the maintenance cover, tighten the screws, and the installation is complete
For more details on maintenance skill,you can check video uploaded on youtube:
https://youtu.be/KX9pYJMy-7Q
How to fix heating element on Dingxin water heater
This part illustrates how to replace the heating tube of a vertical machine.
1. Loosen the screw of the maintenance cover at the bottom of the machine and remove the maintenance cover.
2. Unscrew the fixing screw of the ground wire, loosen the fixing screws of the temperature thermal cut and the tank flange, and take out the thermostat,
3. Pull out the thermostat and temperature limiter temperature probe, unplug the positive and negative terminals of the heating tube, and loosen the five fixing screws on the flange of the heating tube
4. Take out the heating tube, replace it with a new one, loosen the five fixing screws on the flange of the heating tube (each screw is tightened slowly in turn), and loosen the fixing screws of the temperature thermal cut and the flange of the liner
5. Reinsert the temperature tube of the thermostat and the temperature thermal cut into the blind pipe of the heating tube, and block the blind tube with a rubber plug to prevent the temperature detection tube from moving relatively. Then, tighten the fixing screws of the temperature thermal cut and fixing seat and of tank flange,plug the heating tube terminal to the two poles of the heating tube.
6. Install the maintenance cover, tighten the screws, and the installation is complete
For more details on maintenance skill,you can check video uploaded on youtube:
Links:
© Zhejiang Dingxin Electrical Appliance Co.,ltd
Modal Dialog
Zhejiang Dingxin Electric Appliance Co.,Ltd.
Address:No 71,Xinyi Road,Sanjiang Street,Shengzhou,Shaoxing,Zhejiang province
Tel:86-575-83793313,Cell:86-18368781663
E-mail:info@dincn.com
Whatsapp:+8618368781663
Wechat:18368781663
Website:www.dincn.com
Modal Dialog
Dingxin has earned the trust from clients and suppliers for over 30 years. We are still going to earn, and manage, this trust in an exceptionally good way, and set value and opinion of our partners as priority.
Our guiding targets:
1) Safe products, manufactured by safe processes
2) Class leading quality and efficiency
3) Correct products delivered on-time
4) Cost- and energy efficient processes
Brand & trademark
Dingxin websites may contain or provide references to trademarks, patents, proprietary information, technologies, products, processes or other proprietary rights to Dingxin Electric Appliance Co.,ltd. No license or rights to any of these trademarks, patents, proprietary information, technologies, products, processes or other proprietary rights of Dingxin is transferred or granted to the user of this website.
A number of the products are protected by certain patents or trademarks. This includes both production technology and / or complete products. The underlying technology for the production under ODM term of the product may be or is Dingxin Hotwaters property.
It is noted that any violation of Dingxin rights will be pursued legally.
Privacy
Dingxin appreciates your visit to our website and that you show interest in our products and services. We want you to make sure that your personal information is processed safely. We will carefully keep your personal information left and use this only for better suggestion to you.
The information will be analyzed as follows: It is collected and stored to help us meet your inquiries about information and provide you with the services you request. Visits on our web pages are tracked so we can assess which parts of the website provide the best services for our users.
We will never sell any of the information captured despite that our web pages likely including links / pointers to other rival w